Applications
- PCMCIA Cards
- Antennas
- Wireless LANs
- Broadband communications
- Instrumentation
- RF Test Ports
- Cellular Telephones
- Global Positioning Systems (GPS)
- Base Stations
- Satellite Reception Terminals
Features
- Mating cycles ≥ 500
- Conforms to CECC 22000 specifications.
- Interface according to CECC 22340, EN 122340
Special Notice
- The specification is listed below for information. All dimensions are fully compatible with Military requirements.
Iprece provides commercial grade connectors, and environmental requirements we can test in-house. - For electrical and mechanical test, we can support most of it in-house.
- If you have any question, please contact our QA Team.
Electrical
Impedance | 50Ω |
Frequency Range | 0 to 6 GHz |
VSWR | ≤1.15 @ DC to 4 GHz
≤1.40 @ 4 to 6 GHz |
RF Leakage | ≤60 dB (flexible cable)
≤70 dB (semi- rigid cable) |
Dielectric Withstanding Voltage | 500 V rms |
Voltage Rating | ≤170 V rms (depending on cable) |
Inner Contact Resistance | ≤10 mΩ |
Outer Contact Resistance | ≤5 mΩ |
Insulation Resistance | ≥1 GΩ |
Mechanical
Mating | Snap-on Coupling |
Connector Durability | ≥500 Cycles (for beryllium copper female contact only) |
Engagement Force | ≤3.4 lbs |
Disengagement Force | 1.4 lbs ~ 3.4 lbs |
Cable Retention Force | ≥7.3 lbs (for RG178)
≥12.1 lbs (for RG316) |
Environmental
Temperature Range | -55° C to 155° C |
Corrosion (Salt Spray) | MIL-STD-202, Method 101, Cond. B |
Vibration | MIL-STD-202, Method 204, Cond. C |
Thermal Shock | MIL-STD-202, Method 107, Cond. F |
Mechanical Shock | MIL-STD-202, Method 213, Cond. B |
Material
Parts Name | Material | Plating |
Body | Brass | Gold or Nickel |
Inner Contact |
Male: Brass
Female: Phosphor Bronze Beryllium Copper |
Gold |
Insulator | PTFE | |
Crimp Ferrule | Annealed Copper | Same as Body |
Note: Other Material/Finish is Available on Request.