- Description
- Features& Advantages
- Mechanical Dimensions
- Electrical Data
- Mechanical Data
- Attenuation at Any Frequency
- Reviews 0
LHF series cables provide low insertion loss within the current industry and have excellent mechanical phase, temperature phase, and attenuation stability. Currently, the highest operating frequency of this series is 67GHz. It uses ultra-low-density PTFE medium and silver-plated copper tape. It is formed by wrapping and shielding. This series of products are widely used in military radars, electronic countermeasures, and high-power applications with highly demanding requirements;
Attenuation vs. Frequency dB/100m
Power Handling vs. Frequency (Maximum)
Phase Stability(Detection method: one rotation along the repeated bending radius)
Amplitude Stability (Detection method: one rotation along the repeated bending radius)
Phase Change vs Temperature (PPM)
Features& Advantages
- Excellent mechanical phase stability
- Excellent IL stability
- Better bending performance, Durable
- High-power
- High shielding efficiency
- Maximum operating frequency DC-67GHz
Mechanical Dimensions
Cable Model |
LHF-260 |
Material |
||
Center Conductor | 0.51 (0.0201) |
Silver Plated Copper |
||
Dielectric |
1.53(0.0602) |
Microporous PTFE |
||
Inner shield |
1.65(0.0650) |
Helical SPC Tape |
||
Inner Tape | 1.95  (0.0768) |
LD PTFE |
||
Outer Braid | 2.20(0.0851) | Silver Plated Copper Braid | ||
Jacket | 2.60(0.0945) |
FEP |
||
Electrical Data
Cable Model | Impedance | Vp (%) | Shield effectiveness | Permittivity | Delay | Capacitance | Voltage Withstand | Peak power | Cut-off Frequency |
LHF-260 |
50Ω |
0.77 |
>90dB |
1.69 |
4.32nS/m | 86.8pF/m |
500 DC |
2.5 KW |
46GHz |
1.312nS/Ft | 26.45pF/Ft |
Mechanical Data
Cable Model | Bend Radius: installation | Bend Radius: repeated | Weight | Temp, Operating & Installation | |||||
LHF-260 |
12 |
mm |
24 |
mm |
18 |
g/m |
-55 +165℃ |
||
0.472440945 | in | 0.94488189 | in | 0.0121 | lbs/ft | -67 +329℉ |
Attenuation at Any Frequency
Frequency (MHz) | 300 | 1000 | 3000 | 6000 | 8000 | 12000 | 18000 | 26500 | 40000 | 50000 | 60000 | 67000 | K1 | K2 |
LHF- 260 | 34.20 | 63.10 | 111.20 | 159.70 | 186.00 | 231.00 | 287.70 | 355.90 | 448.00 | 508.50 | 564.70 | 601.90 | 1.9500000 | 0.0014500 |
Attenuation at Any Frequency = [ k1 x SQRT (Fmhz)] + [ k2 x Fmhz ]; dB per 100 meter