- The RG179 Coax Cable is a 75-ohm coax cable used in a variety of applications including security systems where high temperature is required.
- With a temperature maximum of 200°C, RG 179 cable also features a small, flexible diameter and a TFE taped outer jacket because of the high-temperature rating.
RG179 Coax Cable Uses and Applications
RG 179 coax cable applications include medical equipment, video security systems, audio security systems (where high-temperature performance is required), and computer applications.
RG 179 Coax Cable Construction
- Conductor:
- Conductor Stranding:Â 7/38
- Number of Strands:Â 7
- Strand Size:Â 38
- Conductor Material:Â Silver-Coated Copper Clad Steel
- Conductor Diameter:Â 0.012 in. (0.305 mm)
- Inner conductor from core:Â .187 inch, maximum
- Inner conductor from the jacket:Â .250 inch, maximum
- Insulation:
- Insulation Diameter:Â 0.063 in. (1.60 mm)
- Dielectric Core:Â Solid, Extruded Polytetrafluoroethylene (PTFE)
- Shield:
- Outer Conductor:Â Single braid of 38 AWG SCCW
- Outer Conductor Diameter:Â 0.084 inches, maximum
- Braid Coverage:Â 92.3%, nominal
- Carriers:Â 16
- Ends:Â 5
- Picks/inch:Â 12.0 +- 10%
- Jacket:
- Jacket: Type IX: FEP
- Jacket Diameter:Â 0.100 inch +- 0.005
- Jacket Type:Â Extruded Fluorinated Ethylene Propylene (FEP)
- Lbs/MFT:Â 9.83
Specification:
Minimum temperature | -55°C |
Maximum temperature | 200°C |
Max Operating Voltage | 1,200 Volts |
Impedance | 75 Ohm |
Capacitance | 23.0 (pF/ft) |
Max Attenuation @ 400 MHz | 21.0 dB/100ft |
Max Power @ 100 MHz | 880 Watts |
Max Power @ 400 MHz | 420 Watts |
Max Power @ 1 GHz | 260 Watts |
Continuous working voltage | 900 V RMS, maximum |
Operating Frequency | 3 GHz, maximum |
Velocity of Propagation | 69.5 percent, nominal |
Inner Conductor DC Resistance | Maximum at 20°C): 24.45 ohms per 100 feet |
Tensile Strength | 50 klb/inch, minimum |
Eccentricity | 10 percent, maximum |
Stress-crack resistance | 230°C + 5°C |
Cold Bend | -55°C 2°C |
Dimensional Stability | 200°C +5°C |
Spark Test | 2,000 V RMS, +10%, -0% |
Voltage withstanding | 2,000 V RMS, +10%, -0% |
Insulation resistance | Not applicable |
Corona extinction voltage | 1,200 V RMS, minimum |
Characteristic impedance | 75 ohms +-3 |
Attenuation | 21.0 dB per 100 feet, maximum, at 0.4 GHz. |
Structural return loss | Not applicable |
Electrical Capacitance | 23.0 pF per foot, maximum |
Max Working Voltage | 900 |
Max Conductor Resistance | 24.5 (80.2) |
Reviews
There are no reviews yet.